04-21-2024, 08:12 PM
Hi i need help i try coded a used amplifier to my vehicule F07
I do this with e-sys
Connect => Read FA (VO) => Activate FA (VO) => Read VCM => Left-Click on AMP => Click on "Detect CAF for SWE" => Select the CAFD from latest I-Level shown (bottom) => Select OK => Right-Click on AMP (the ECU itself not the underlying CAFD) => Select CODE
But i got this error
Caf's suchen
Tal wird generiert
Abarbeitung wird gestartet
Read SVT before TAL execution started.
Read SVT before TAL execution finished.
TAL execution started.
ExecutionID=2024/04/21-13:28:30.939
[] prepareTALExecution started [PROGRESS]
[] prepareTALExecution finished [PROGRESS]
[] prepareVehicleForCoding started [PROGRESS]
[] prepareVehicleForCoding finished [PROGRESS]
MCDDiagService<id=46634, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: negative response : conditionsNotCorrect, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
MCDDiagService<id=46900, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: timeout, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
MCDDiagService<id=46900, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: timeout, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
[AMP_TOPHB - 37] There was an error during TAL execution, please check the log files. [WARN]
[AMP_TOPHB - 37] - [Exception - AMP_TOPHB - 37] negative response error:
code: TIMEOUT P2/T2 occurred
description: P2 timeout on Service RDBI_SVK has error in result: [Severity=2051][ErrorCode=58640][ErrorCodeDescription=resource not available][VendorCode=2142][VendorCodeDescription=P2 timeout occured]; LinkName: AMP_TOPHB_37_ETHERNET
severity: ERROR
[] null [THROWABLE]
[] finalizeVehicleCoding started [PROGRESS]
[] finalizeVehicleCoding finished [PROGRESS]
[] finalizeTALExecution started [PROGRESS]
[] finalizeTALExecution finished [PROGRESS]
TAL execution finished [TAL_EXECUTION_FINISHED]
TAL-Execution finished with status: "FinishedWithError". [C207]
TAL execution finished. Duration: "15s". [C206]
Read SVT after TAL execution started.
MCDDiagService<id=46600, job=com.bmw.psdz.jobs.common.MCD3_GenerateConfigFromVehicle, service=RDBI_SVK, description=error: negative response : conditionsNotCorrect, link=#RtGen_MultipleEcuJob_LogicalLink> [DIAGSERVICE]
MCDDiagService<id=46634, job=com.bmw.psdz.jobs.common.MCD3_GenerateConfigFromVehicle, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: negative response : conditionsNotCorrect, link=AMPT_37_ETHERNET> [DIAGSERVICE]
Read SVT after TAL execution finished.
Abarbeitung beendet
I do this with e-sys
Connect => Read FA (VO) => Activate FA (VO) => Read VCM => Left-Click on AMP => Click on "Detect CAF for SWE" => Select the CAFD from latest I-Level shown (bottom) => Select OK => Right-Click on AMP (the ECU itself not the underlying CAFD) => Select CODE
But i got this error
Caf's suchen
Tal wird generiert
Abarbeitung wird gestartet
Read SVT before TAL execution started.
Read SVT before TAL execution finished.
TAL execution started.
ExecutionID=2024/04/21-13:28:30.939
[] prepareTALExecution started [PROGRESS]
[] prepareTALExecution finished [PROGRESS]
[] prepareVehicleForCoding started [PROGRESS]
[] prepareVehicleForCoding finished [PROGRESS]
MCDDiagService<id=46634, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: negative response : conditionsNotCorrect, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
MCDDiagService<id=46900, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: timeout, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
MCDDiagService<id=46900, job=com.bmw.psdz.jobs.uds.MCD3_GetSVKfromECU, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: timeout, link=AMP_TOPHB_37_ETHERNET> [DIAGSERVICE]
[AMP_TOPHB - 37] There was an error during TAL execution, please check the log files. [WARN]
[AMP_TOPHB - 37] - [Exception - AMP_TOPHB - 37] negative response error:
code: TIMEOUT P2/T2 occurred
description: P2 timeout on Service RDBI_SVK has error in result: [Severity=2051][ErrorCode=58640][ErrorCodeDescription=resource not available][VendorCode=2142][VendorCodeDescription=P2 timeout occured]; LinkName: AMP_TOPHB_37_ETHERNET
severity: ERROR
[] null [THROWABLE]
[] finalizeVehicleCoding started [PROGRESS]
[] finalizeVehicleCoding finished [PROGRESS]
[] finalizeTALExecution started [PROGRESS]
[] finalizeTALExecution finished [PROGRESS]
TAL execution finished [TAL_EXECUTION_FINISHED]
TAL-Execution finished with status: "FinishedWithError". [C207]
TAL execution finished. Duration: "15s". [C206]
Read SVT after TAL execution started.
MCDDiagService<id=46600, job=com.bmw.psdz.jobs.common.MCD3_GenerateConfigFromVehicle, service=RDBI_SVK, description=error: negative response : conditionsNotCorrect, link=#RtGen_MultipleEcuJob_LogicalLink> [DIAGSERVICE]
MCDDiagService<id=46634, job=com.bmw.psdz.jobs.common.MCD3_GenerateConfigFromVehicle, service=RDBI_SVK - ReadDataByIdentifier SVK, description=error: negative response : conditionsNotCorrect, link=AMPT_37_ETHERNET> [DIAGSERVICE]
Read SVT after TAL execution finished.
Abarbeitung beendet