Bimmer Scene - Latest BMW Coding / Retrofits / Maps

Full Version: ISTA Standalone / SQLiteDBs / SDP / BLP - latest [TORRENT] with installer EASY
You're currently viewing a stripped down version of our content. View the full version with proper formatting.
This is exactly what is was looking for
Thank you
(08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]This thread is for my Standalone Releases, always the latest. HUGE THANKS TO SEDOY FROM CT

Please REP & Thank you if this helps you

If you have no idea how to install ISTA manually, use my installer!!!

Please don't ask me for another language!!!


ISTA Standalone

* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)

- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.

Installer need this structure (see attachment):
Downloaddirectory
|  ista_standalone_installer_4.27.13.exe
|  ISTA_v4.27.13.22475.7z (required)
|  BLP_4.27.11.7z (required)
|  SDP_4.26.35.7z (if needed)
|
\---SQLiteDBs
        EN_4.27.12.7z (required)
        DE_4.27.12.7z (if needed)
        ZH_4.27.12.7z (if needed and if available)
        GLOBAL_4.27.12.7z (required)



Standalone: ISTA 4.27.13.22475 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.27.12 / BLP 4.27.11 / SDP 4.26.35

Standalone Installer (all above files/dirs must be present in the same directory):  v4.27.13





Standard Tools Installer (Ediabas, INPA, NCS Expertentool, etc. ECU and SGDAT updated with v66.2)
SP-Daten v67.1.006


Tip: to download from Mega use MegaSync with Free/Pro Mega-Account, or jDownloader. MegaSync with free-account will continue after a break, be patient.
Quote:
You have not unlocked this post's content yet. Please reply to this thread to unlock the content.

Thank you!
Thank you [url=https://www.bimmerscene.com/User-XuLeTZ]

Can you please advise me if I need PZdata or PZdata lite in addition to your stuff?
And is it required if I am not doing programming
(12-06-2020, 02:04 PM)peter_pan Wrote: [ -> ]Thank you [url=https://www.bimmerscene.com/User-XuLeTZ]

Can you please advise me if I need PZdata or PZdata lite in addition to your stuff?
And is it required if I am not doing programming
bop is lite and sdp is full.
You don't need sdp if you only use Ista for Diagnose. For programming you need SDP.
basically BLP is psdzdata lite and SDP is psdzdata full.
Read before asking please:

- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).

- for Programming is SDP needed, using older Versions allowed.
thank you, perfect service
I've been looking for an easy stanadalone ISTA installer. thank you!
Awesome, thanks!!!
(08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]This thread is for my Standalone Releases, always the latest. HUGE THANKS TO SEDOY FROM CT

Please REP & Thank you if this helps you

If you have no idea how to install ISTA manually, use my installer!!!

Please don't ask me for another language!!!


ISTA Standalone

* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)

- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.

Installer need this structure (see attachment):
Downloaddirectory
|  ista_standalone_installer_4.27.13.exe
|  ISTA_v4.27.13.22475.7z (required)
|  BLP_4.27.11.7z (required)
|  SDP_4.26.35.7z (if needed)
|
\---SQLiteDBs
        EN_4.27.12.7z (required)
        DE_4.27.12.7z (if needed)
        ZH_4.27.12.7z (if needed and if available)
        GLOBAL_4.27.12.7z (required)



Standalone: ISTA 4.27.13.22475 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.27.12 / BLP 4.27.11 / SDP 4.26.35

Standalone Installer (all above files/dirs must be present in the same directory):  v4.27.13





Standard Tools Installer (Ediabas, INPA, NCS Expertentool, etc. ECU and SGDAT updated with v66.2)
SP-Daten v67.1.006


Tip: to download from Mega use MegaSync with Free/Pro Mega-Account, or jDownloader. MegaSync with free-account will continue after a break, be patient.
Quote:
You have not unlocked this post's content yet. Please reply to this thread to unlock the content.


Thank you!
thank you Smile))))
This is great thank you