01-11-2021, 10:49 PM
Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142
01-12-2021, 10:34 PM
(08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]This thread is for my Standalone Releases, always the latest. HUGE THANKS TO SEDOY FROM CT andThanksfor helping with google drive for faster download rates
Please REP & Thank you if this helps you
If you have no idea how to install ISTA manually, use my installer!!!
Please don't ask me for another language!!!
ISTA Standalone
* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)
- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.
Installer need this structure (see attachment):
Downloaddirectory
| ista_standalone_installer_4.27.22.exe
| ISTA_v4.27.22.22497.7z (required)
| BLP_4.27.20.7z (required)
| SDP_4.27.20.7z (if needed)
|
\---SQLiteDBs
EN_4.27.20.7z (required)
DE_4.27.20.7z (if needed)
ZH_4.27.20.7z (if needed and if available)
GLOBAL_4.27.20.7z (required)
Standalone: ISTA 4.27.22.22497 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.27.20 / BLP 4.27.20 / SDP 4.27.20
Standalone Installer (all above files/dirs must be present in the same directory): v4.27.22
Standard Tools Installer (Ediabas, INPA, NCS Expertentool etc. ECU and SGDAT updated with v66.2)
01-13-2021, 08:46 AM
(10-02-2020, 02:57 AM)kensys1 Wrote: [ -> ](09-24-2020, 05:40 AM)bhuriponk Wrote: [ -> ](08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]Thanks to Sedoy from CT Thank bro
Quote:This Thread is for my Standalone Releases, always latest.
If you have no idea how to install ISTA manually, use my installer!!!
Please don't ask me for another Languages!!!
ISTA Standalone
* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)
- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.
Installer need this structure (see attachment):
Downloaddirectory
| ista_standalone_installer_4.25.20.exe
| ISTA_v4.25.20.21842.7z (required)
| BLP_4.25.21.7z (required)
| SDP_4.25.21.7z (if needed)
|
\---SQLiteDBs
EN_4.25.20.7z (required)
DE_4.25.20.7z (if needed)
ZH_4.25.20.7z (if needed and if available)
GLOBAL_4.25.20.7z (required)
Standalone: ISTA 4.25.20.21842 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.25.20 / BLP 4.25.21 / SDP 4.25.21
Standalone Installer (all above files/dirs must be present in the same directory): v4.24.20
PSdZData Lite: v4.25.21
Standard Tools Installer (Ediabas, INPA, NCS Expertentool etc. ECU and SGDAT updated with v66.2)
SP-Daten v67.1.006
Tip: to download from Mega use MegaSync with Free/Pro Mega-Account, or jDownloader. MegaSync with free-account will continue after a break, be patient.
To bypass the download exceeded quota, use freedome VPN, you have 5 days for trial and many location to complete the download in no time.
Google Drive LINK ADDED
You have not unlocked this post's content yet. Please reply to this thread to unlock the content.
thanks
Tanks!
(09-24-2020, 05:40 AM)bhuriponk Wrote: [ -> ](08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]Thanks to Sedoy from CT Thank bro
Quote:This Thread is for my Standalone Releases, always latest.
If you have no idea how to install ISTA manually, use my installer!!!
Please don't ask me for another Languages!!!
ISTA Standalone
* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)
- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.
Installer need this structure (see attachment):
Downloaddirectory
| ista_standalone_installer_4.25.20.exe
| ISTA_v4.25.20.21842.7z (required)
| BLP_4.25.21.7z (required)
| SDP_4.25.21.7z (if needed)
|
\---SQLiteDBs
EN_4.25.20.7z (required)
DE_4.25.20.7z (if needed)
ZH_4.25.20.7z (if needed and if available)
GLOBAL_4.25.20.7z (required)
Standalone: ISTA 4.25.20.21842 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.25.20 / BLP 4.25.21 / SDP 4.25.21
Standalone Installer (all above files/dirs must be present in the same directory): v4.24.20
PSdZData Lite: v4.25.21
Standard Tools Installer (Ediabas, INPA, NCS Expertentool etc. ECU and SGDAT updated with v66.2)
SP-Daten v67.1.006
Tip: to download from Mega use MegaSync with Free/Pro Mega-Account, or jDownloader. MegaSync with free-account will continue after a break, be patient.
To bypass the download exceeded quota, use freedome VPN, you have 5 days for trial and many location to complete the download in no time.
Google Drive LINK ADDED
You have not unlocked this post's content yet. Please reply to this thread to unlock the content.
Tanks
Thank you for the psdzdata v4.25.3
Thank you for sharing
01-14-2021, 06:34 AM
can anybody help with russian SQLiteDBs ?
01-17-2021, 09:46 AM
thanks
01-17-2021, 09:17 PM
(08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]This thread is for my Standalone Releases, always the latest. HUGE THANKS TO SEDOY FROM CT andThank you so much!for helping with google drive for faster download rates
Please REP & Thank you if this helps you
If you have no idea how to install ISTA manually, use my installer!!!
Please don't ask me for another language!!!
ISTA Standalone
* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)
- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.
Installer need this structure (see attachment):
Downloaddirectory
| ista_standalone_installer_4.27.22.exe
| ISTA_v4.27.22.22497.7z (required)
| BLP_4.27.20.7z (required)
| SDP_4.27.20.7z (if needed)
|
\---SQLiteDBs
EN_4.27.20.7z (required)
DE_4.27.20.7z (if needed)
ZH_4.27.20.7z (if needed and if available)
GLOBAL_4.27.20.7z (required)
Standalone: ISTA 4.27.22.22497 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.27.20 / BLP 4.27.20 / SDP 4.27.20
Standalone Installer (all above files/dirs must be present in the same directory): v4.27.22
Standard Tools Installer (Ediabas, INPA, NCS Expertentool etc. ECU and SGDAT updated with v66.2)
01-18-2021, 08:21 PM
than you mucho.
01-19-2021, 08:07 AM
(08-17-2020, 10:29 PM)XuLeTZ Wrote: [ -> ]This thread is for my Standalone Releases, always the latest. HUGE THANKS TO SEDOY FROM CT andfor helping with google drive for faster download rates
Please REP & Thank you if this helps you
If you have no idea how to install ISTA manually, use my installer!!!
Please don't ask me for another language!!!
ISTA Standalone
* resolution can be changed in the ISTAGUI.exe.config
* disable CheckSystemRequirements is now possible in ISTAGUI.exe.config
* enable programming with ENET is now possible in ISTAGUI.exe.config (at your own risk.)
* enable Diagnose for J29 (Toyota Supra) is now possible in ISTAGUI.exe.config.
* "Unknown terminal voltage!" message with ENET is fixed, now ISTA check really Voltage, but not display it.
* don't ask me to remove "Unknown terminal voltage!" message, this is a important message!!!
* read FASTA Data from Vehicle is disabled in ISTAGUI.exe.config
* if you use my Regfiles, open it with Notepad and change the InstallLocation to the right Location on her PC. (not needed with Installer)
- for Diagnose only, neccessary SQLiteDBs GLOBAL(required), en-GB(required), de-DE(optional) and BLP(required) in the same Version as App (example 4.25.1x).
- for Programming is SDP needed, using older Versions allowed.
Installer need this structure (see attachment):
Downloaddirectory
| ista_standalone_installer_4.27.22.exe
| ISTA_v4.27.22.22497.7z (required)
| BLP_4.27.20.7z (required)
| SDP_4.27.20.7z (if needed)
|
\---SQLiteDBs
EN_4.27.20.7z (required)
DE_4.27.20.7z (if needed)
ZH_4.27.20.7z (if needed and if available)
GLOBAL_4.27.20.7z (required)
Standalone: ISTA 4.27.22.22497 / SQLiteDBs (OTHER,en-GB,de-DE,zh-CN,it-IT) 4.27.20 / BLP 4.27.20 / SDP 4.27.20
Standalone Installer (all above files/dirs must be present in the same directory): v4.27.22
Standard Tools Installer (Ediabas, INPA, NCS Expertentool etc. ECU and SGDAT updated with v66.2)
many thnxs for this posting
01-19-2021, 07:23 PM
Just wanted to update anyone having problems using the USB K+DCAN K+CAN. Follow the below instructions
1. Plug your K+D-CAN cable and install drivers. For FTDI based cables use latest drivers.
2. Open “Device Manager”, then USB Serial Port properties, go to “Port Settings” tab and click
“Advanced...”. Change port number to “COM1” and latency timer to “1”. Confirm configuration
via “OK” button.
3. Open C:\RHEINGOLD\EDIABAS\BIN\EDIABAS.INI with Notepad and check for “Interface = REMOTE and change to STD:OBD”.
4. In TCP settings confirm “Port = 6801”.
5. Close EDIABAS.INI Open ISTA and go to “Settings > Vehicle interface” and select “Ediabas default settings (ediabas.ini)”, then “OK”.
That is what I did, and everything is working perfectly. My COM was set to COM9. It needs to be changed to work correctly.
Appreciate the files!
1. Plug your K+D-CAN cable and install drivers. For FTDI based cables use latest drivers.
2. Open “Device Manager”, then USB Serial Port properties, go to “Port Settings” tab and click
“Advanced...”. Change port number to “COM1” and latency timer to “1”. Confirm configuration
via “OK” button.
3. Open C:\RHEINGOLD\EDIABAS\BIN\EDIABAS.INI with Notepad and check for “Interface = REMOTE and change to STD:OBD”.
4. In TCP settings confirm “Port = 6801”.
5. Close EDIABAS.INI Open ISTA and go to “Settings > Vehicle interface” and select “Ediabas default settings (ediabas.ini)”, then “OK”.
That is what I did, and everything is working perfectly. My COM was set to COM9. It needs to be changed to work correctly.
Appreciate the files!
01-19-2021, 09:55 PM
(01-19-2021, 07:23 PM)BMWHoochie Wrote: [ -> ]Just wanted to update anyone having problems using the USB K+DCAN K+CAN. Follow the below instructionsThanks for info, but ISTA doesn`t use the EDIABAS from C:/ drive.It has it's own ediabas configuration which is in Rheingold\Ediabas
1. Plug your K+D-CAN cable and install drivers. For FTDI based cables use latest drivers.
2. Open “Device Manager”, then USB Serial Port properties, go to “Port Settings” tab and click
“Advanced...”. Change port number to “COM1” and latency timer to “1”. Confirm configuration
via “OK” button.
3. Open C:\EDIABAS\BIN\EDIABAS.INI with Notepad and check for “Interface = REMOTE and change to STD:OBD”.
4. In TCP settings confirm “Port = 6801”.
5. Close EDIABAS.INI Open ISTA and Select “VCI Config” tab and select “Ediabas standard settings (ediabas.ini)”, then “OK”.
That is what I did, and everything is working perfectly. My COM was set to COM9. It needs to be changed to work correctly.
Appreciate the files!
Glad it worked for you that way. Usually i`m changing the settings from Settings > Vehicle interface when I`m plugging in the K+D-Can cable
Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142